Electrocardiographs (ECGs), electromyographs (EMGs), and electroencephalographs (EEGs) are medical devices that monitor the electrical activity of the heart, muscles, and brain by measuring the potential differences on the surface of living tissues. These tools play a crucial role in diagnosing various conditions, but clinicians often encounter several practical challenges when performing biopotential measurements. This article will discuss these issues and explore effective solutions to improve accuracy and reliability.
Biopotential measurements rely on electrodes placed on the skin to detect small electrical signals generated by the body. For instance, ECGs track the heart's electrical impulses, EMGs measure muscle activity, and EEGs record brainwave patterns. These signals are influenced by the movement of ions within the body, and proper electrode placement is essential for accurate readings. A biopotential electrode is used to capture these signals effectively.
However, achieving consistent and reliable results can be challenging. One common issue is improper skin preparation before electrode placement. If the skin isn't cleaned or properly prepped, it can lead to poor signal quality and difficulty in capturing clear data. Additionally, factors such as age, race, and skin condition can affect impedance levels, which vary from patient to patient. Gold electrodes, commonly used in ECGs, tend to have higher impedance compared to silver/silver chloride electrodes used in EMGs and EEGs. Moreover, interference from other medical equipment—such as ablation devices, electric cautery, defibrillators, pacemakers, and external pacing systems—can significantly impact measurement accuracy.
To address these challenges, system design plays a key role. Ensuring that the signal conditioning circuitry is well-designed helps maintain high measurement reliability and reduces the need for frequent electrode replacements. Poor contact between the electrode and the skin can cause the front-end amplifier’s input bias current to polarize the electrode, leading to signal distortion. To mitigate this, low-input bias current amplifiers are essential. The AD8625/AD8626/AD8627 family of JFET input operational amplifiers features an input bias current of less than 1 pA, while the AD8220 and AD8224 JFET instrumentation amplifiers offer even lower bias currents, below 20 pA.
Amplifiers with wide supply voltage ranges are also beneficial in noisy clinical environments, such as emergency rooms and operating theaters. They can handle a broad input voltage range and provide high gain, ensuring stable performance under varying conditions. For example, the AD8625/AD8626/AD8627 series operates from a single 5V to 26V power supply, offering flexibility in different setups. The AD8220 and AD8224 can run on a dual ±18V supply or a single 5V supply, both providing rail-to-rail output for maximum dynamic range. Their quiescent current is only 750μA, making them ideal for battery-powered applications. Additionally, the AD8224 can be configured as a single-channel differential output instrumentation amplifier, offering excellent noise immunity and versatility for various clinical needs.